DOE-HDBK-1143-2001
Student's Guide
1. Summary of dose limits
10 CFR Part 835 employs the rem unit for
several different physical quantities (i.e.
absorbed dose, effective dose equivalent,
total effective dose equivalent, dose
equivalent, committed dose equivalent,
committed effective dose equivalent). For
information about these quantities refer to 10
CFR Part 835 definitions. This training will
use the term "dose" as a general term for all
the above terms.
These are the Federal limits. DOE
encourages sites to adopt more restrictive
Administrative Control Levels (ACLs). For
most facilities an ACL of 500 mrem or less
will be challenging for radiological workers.
Exposed Individual
Annual Limit
General Employee: Whole Body (internal and external) (TEDE)
5.0 rem
General Employee: Lens of Eye (DE)
15.0 rem
General Employee: Extremity (below elbow and knees) and skin (SDE)
50.0 rem
General Employee: Any Organ or Tissue (other than lens of eye) (DDE + CDE)
50.0 rem
Declared Pregnant Worker: Embryo/Fetus (gestation period) (DE)
0.5 rem
Occupationally Exposed Minors (under age 18): ((TEDE)
0.1 rem *
Members of the Public in Controlled Areas: (TEDE)
0.1 rem
And 10% of other general employee limit
Module 2 - 5