Click here to make tpub.com your Home Page

Page Title: Table 5.6. Intake Retention Fractions(a) for 239Pu
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 



DOE-STD-1128-98
Guide of Good Practices for Occupational Radiological Protection in Plutonium Facilities
Table 5.6. Intake Retention Fractions(a) for 239Pu
Class W
Class Y
Days Post-
Intake
Lung
Urine
Feces
Lung
Urine
Feces
1
2.16E-01
2.36E-04
1.05E-01
2.14E-01
1.28E-05
1.27E-01
2
1.78E-01
1.61E-04
1.34E-01
1.81E-01
8.71E-06
1.56E-01
7
1.39E-01
3.29E-05
6.41E-03
1.50E-01
1.69E-06
5.20E-03
14
1.26E-01
2.18E-05
1.23E-03
1.48E-01
1.09E-06
1.73E-04
30
1.03E-01
1.73E-05
9.58E-04
1.45E-01
8.60E-07
1.34E-04
60
7.01E-02
1.34E-05
6.34E-04
1.41E-01
7.15E-07
1.29E-04
90
4.77E-02
1.15E-05
4.21E-04
1.37E-01
6.89E-07
1.23E-04
180
1.50E-02
8.31E-06
1.26E-04
1.25E-01
7.19E-07
1.09E-04
365
1.36E-03
4.84E-06
1.39E-05
1.04E-01
7.97E-07
8.46E-05
730
1.09E-05
2.45E-06
2.50E-06
7.31E-02
8.85E-07
5.14E-05
1825
0.00E+00
1.63E-06
1.63E-06
2.90E-02
8.82E-07
1.19E-05
3650
0.00E+00
1.54E-06
1.54E-06
9.60E-03
7.38E-07
1.36E-06
7300
0.00E+00
1.38E-06
1.38E-06
4.16E-03
6.09E-07
6.15E-07
18250
0.00E+00
1.00E-06
1.00E-06
3.70E-03
4.38E-07
4.39E-07
(a) Calculated using GENMOD Computer Code Version 3.0.3(2), assuming 1-m AMAD aerosol.
5.8.2
Alternate Methods of Intake Assessment
Historically, intake as described in an in the foregoing section was not always calculated
when assessing plutonium exposures. Estimates of uptake using methods similar to
Langham (1956), Healy (1957), or Lawrence (1987) focused on assessing the magnitude of
radioactivity retained in an in the body, rather than intake (which includes material not
retained and of no dosimetric significance). These methods were (and are) dosimetrically
sound in an in so far as estimates of deposition and uptake are concerned, but do not meet
the current regulatory requirement of 10 CFR 835 (DOE, 1998a) to calculate intake.
5.8.3
Estimating Effective Dose Equivalent from Intakes of Plutonium
The committed dose equivalent resulting from an intake of plutonium may be calculated by
multiplying the estimated intake (I) by an appropriate dose conversion factor (DCF):
H 50 =
I*DCF
(5.8)
5-32