DOE-HDBK-1203-97
-
power defect
-
pressure coefficient
-
void coefficient
Evaluate the impact of decay heat generation on post-trip operations for
varying facility conditions
Describe the bases for limits on power escalation and dissension
Calculate reactivity balance, critical rod position, shutdown margin, and
inverse count-rate ratios (1/m)
Determine the effect of poison concentration and loading on reactivity control
and fuel management for the following:
-
fission product poisons
-
burnable poisons
-
nonburnable poisons
Determine the effect of each of the following on reactivity control and facility
operations:
-
thermal hydraulic limits
-
linear heat generation rates
-
minimum critical power ratio
-
average planar linear heat generation rate
-
peaking factors
Evaluate the effect of the following on reactivity control and facility operations:
-
unbalanced core flow
-
recirculation flow changes
-
control rod movements
-
natural circulation
-
thermal-hydraulic instabilities
-
main generator load changes
-
inadvertent changes in burnable poison concentration
-
xenon and samarium concentration
Discuss the ways to prevent, identify, and mitigate operation with failed fuel.