DOE-HDBK-6004-99
Potential Safety Functions
The cooling system potential safety functions for design basis accidents are:
1. Remove heat from safety-class structures, systems and components.
2. Transfer the combined heat load to a safety-class heat sink.
3. Partially confine radioactivity entrained or deposited in the coolant system, and provide for
suitable releases to environment or transfer to a waste facility.
4. For a large break in the cooling system pressure boundary:
a)
Provide makeup coolant at a sufficient rate that the system' heat removal and rejection
s
capacity will prevent damage of safety-class structures, systems or components while
allowing only negligible materials reactions with the coolant.
b)
Collect coolant spilled from a large break to prevent damage to safety-class structures,
systems or components.
Beyond Design Basis Accidents
Beyond design basis accidents include internal and external initiators whose frequencies are lower
than the design basis frequency limit specified in the safety analysis. There are no cooling system
safety functions for beyond design basis accidents.
Safety Design Standards and Criteria
Structures, systems and components needed to perform safety functions should be designated safety
class. Components which do not perform safety functions but whose single failure causes loss of a
safety function should also be designated safety class. Included in the safety-class are:
1. Gauges, instrument tubing, sensing lines, stubs and other pressure containing hardware on the
pressure boundary of the safety-class coolant system,
2. Membrane interfaces and isolation devices between safety-class and non-safety-class coolant
systems.
The different designs and operating characteristics of fusion facilities limit the amount of specific
guidance that these criteria can provide. Existing DOE and NRC design requirements and guidance
documents provide helpful general guidance for implementing these criteria at a particular fusion
facility.
For safety-class cooling systems, the following design standards and criteria should apply to the
structures, systems and components.