DOE-HDBK-6004-99
Past Design Practices
Activation Control Methods
The choice of materials of construction is the only known means of minimizing the activation of
materials from neutron bombardment. For metallic materials, the over riding structural and
contamination concerns require the usage of activating materials, usually stainless steel. For non-
metallic materials, if possible, materials of lower activation potential should be utilized, for greases,
elastomers, etc.
Contamination Control Methods
Tritium contamination is volumetric in nature and can not be easily eliminated. The contamination
by other materials can be minimized by surface condition induced entrapment. Smooth surfaces and
no surface coatings will both minimize contamination and simplify decontamination.
Electronics Protection Methods
The very high electrical and magnetic normal and transient fields potentially present in the fusion
facility will present a hazard to all electronics systems. Maximum protection should be provided for
all interferences that will normally occur as to not interfere with routine operation of remote handling
operations. The off normal interferences should not prevent safe retrieval of equipment for repair,
and must not introduce unwanted motions; but off normal excursions may result in discontinuation
of operation.
Internal Wiring Methods
Wiring through sections and/or modules of remote handling equipment should be provided within the
equipment. Externally deployed wiring is expected to present an undesirable hazard to operations.
The damage to or damage by externally routed cabling has historically represented an impediment to
successful operation. The wiring connectors between sections should also be internal, for operability
reasons and to address the requirements shown in the following section.
Operational Requirements
Mode of Operation
The remote handling systems may be operated in the following modes:
Fully Robotic
Telerobotic
Teleoperation
Manual
101