Figure 7. BORAX V Superheater Fuel Subassembly


DOE-STD-3007-93
fuel assemblies. Current inventory fuel storage maps indicate that no more than three assemblies
are stored per bucket. Since only three fuel assemblies are stored per bucket, a more realistic
configuration is given at the bottom of Figure 9. As shown in this case, the fuel assemblies are
arranged in a staggered configuration. The result calculated in this case yields an effective
multiplication factor of keff+ 2s = 0.9340, which is within the ICCP acceptance criteria.
A revision to the current technical specification, TS/S 4.6A1, will allow only three
assemblies per bucket when stored on the basin floor. This revision will redefine approved
storage to allow these buckets to be stored on the floor of a storage channel with no spacing