Quantcast Table 3. Results of ANISN calculations for spheres of Pu-239 reflected

 

Click here to make tpub.com your Home Page

Page Title: Table 3. Results of ANISN calculations for spheres of Pu-239 reflected
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
Evaluation and Results cont'd - s3007cn10082
Up
Guidelines For Preparing Criticality Safety Evaluations at Department of Energy Non-Reactor Nuclear Facilities
Next
Figure 1. Calculated k-effective versus H/Pu-239 ratio


DOE-STD-3007-93
Case
Pu Mass
H/Pu
Sphere Radius
ID
(g)
(cm)
k-effective
0.9257
11.93127
1
300
700
0.9311
12.47435
800
0.9332
12.97377
900
0.9324
13.43755
1000
0.9298
13.87125
1100
2
325
700
12.25389
0.9438
800
12.81164
0.9489
900
13.32464
0.9506
1000
13.80092
0.9494
1100
14.24642
0.9464
3
350
700
12.56036
0.9606
800
13.13208
0.9653
900
13.65783
0.9665
1000
14.14067
0.9651
1100
14.60264
0.9616
4
400
700
13.13206
0.9904
800
13.72979
0.9944
900
14.27948
0.9950
1000
14.78994
0.9928
1100
15.26729
0.9887
5
425
700
13.40014
1.0039
800
14.01007
1.0076
900
14.57098
1.0078
1000
15.09186
1.0053
1100
15.57895
1.0008
4-14


Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc.