allow for the accurate assessment of radiological hazards,
including radioactive hot particles. All radiological-release
surveys of outgoing tools and equipment from the RCA, should
be recorded to document compliance with acceptable
contamination and radioactive material control policies. Such
items should be released only by qualified and authorized
personnel and with the items tagged or marked as releasable to
noncontrolled areas of the facility. The attached tag or marker
should include written approval from both the responsible
department and by authorized radiological protection personnel.
3.4.4.4 Dry radioactive-waste containers, as well as collection and sorting areas,
should be monitored frequently (after establishing a tool control
program) and periodically thereafter. This monitoring should include the
recording of tools and equipment found in radioactive-waste receptacles,
to determine the extent at which losses of these potentially contaminated
items are occurring and to identify the source or reason for the losses.
This information should be used to correct the problems as soon as
possible. Problems experienced should be included in "lessons learned" to
aid future planning.