Click here to make tpub.com your Home Page

Page Title: Bioassay program for tritium workers
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 



Radiological Assessor Training
DOE-HDBK-1141-2001
Student's Guide
J. Bioassay program for tritium workers
An adequate bioassay program for tritium
workers would test for chronic and acute
exposure.
1. Chronic exposure - Periodic urinanalysis for
tritium (daily to biweekly identified in Tritium
Good Practices Manual)
2. Acute exposure
Wait one to two hours.
Void bladder.
Collect sample as soon as possible
thereafter.
Continue to collect daily to determine
individual half-life.
Dose from exposure to STCs may need to be
assessed based on air monitoring results, see
RCTP 99-02.
DOE-STD-1121-99, Internal Dosimetry, 1999,
provides guidance on internal dosimetry
programs including monitoring and assessing
dose from tritium.
K. Tritium effluent recovery systems
1. Purpose - Reduce tritium available for
.
release
2. Method - Tritium gas converted to HTO and
ultimately a stable waste form
Module 7 - 11