| Radiological Assessor Training
DOE-HDBK-1141-2001
Student's Guide
I. Inventory control and accountability requirements
Real-time or near real-time accountability systems
should be incorporated if possible.
J.
Criticality safety considerations
Criticality alarm systems (gamma or neutron) shall
be provided in each area where an accidental
criticality is possible.
Criticality safety requirements may include:
ANSI/ANS 8.3-1986, Criticality Accident Alarm
Systems; ANSI/ANS 8.1-1983, Nuclear Criticality
Safety in Operations with Fissionable Materials
Outside Reactors; and ANSI/ANS 8.19-1984,
ANS Administrative Procedures for Nuclear
Criticality.
It is important to review site requirements
documents prior to conducting the assessment.
All DOE facilities that possess sufficient quantities
and kinds of fissile material to potentially
constitute a critical mass shall provide nuclear
accident dosimetry.