| Radiological Control Training for Supervisors
DOE-HDBK-1143-2001
Student's Guide
2. For a declared pregnant worker who chooses
to continue working as a radiological worker
the following apply:
The dose limit for the embryo/fetus for the
entire gestation period shall be no greater
than 500 mrem.
Substantial variation above a uniform
exposure rate that would satisfy the limits
shall be avoided (e.g. 50 mrem/month).
3. If the dose to the embryo/fetus is determined
to have already exceeded 500 mrem when a
worker notifies her employer of her
pregnancy, the worker shall not be assigned
to tasks where additional occupational
radiation exposure is likely during the
remainder of the gestation period.
VII. Respirator protection
There are three main requirements that must be
met by personnel prior to being issued a respirator.
Personnel must be trained, fitted, and medically
qualified to wear that specific type of respirator.
Training and qualification testing shall be performed
annually.
A. Respirator use
While using respiratory protection, personnel are
expected to:
1. Perform fit checks of their respirators to
ensure a proper seal before entering areas
requiring respirator use.
Module 4 - 5
|