| DOE-HDBK-1106-97
Lesson Plan
Instructor's Notes
EO6: DEFINE
2. Contamination Area
Contamination Area, High
Contamination Area, and
Any area where removable contamination levels are
Airborne Radioactivity Area.
greater than the values specified in Appendix D of 10
Reference: 10 CFR
CFR 835, but less than or equal to 100 times those
835.2(a), 835.603(e), and
levels.
Appendix D of 10 CFR
835.
The posting/signs will indicate:
"CAUTION, CONTAMINATION AREA"
Abbreviated Table of Contamination Values
(See 10 CFR 835 Appendix D for complete listing)
TOTAL dpm/ 100 cm2
NUCLIDE
REMOVABLE
I-125, I-129
20
500
I-131, I-133
200
1,000
Beta/gamma
1,000
5,000
Tritium
10,000
N/A
24
|