DOE-HDBK-1106-97
Lesson Plan
Instructor's Notes
D.
Indicators of Possible Area Contamination
The following are some indicators of possible area
contamination:
1. Visual indicators, such as:
 Leaks, spills, standing liquids.
 Damaged radiological containers.
2. Detection of contamination or elevated radiation
levels including:
 Spurious or unexplained personnel contamination.
Presence of higher than
Radioactivity observed in bioassay samples
background levels of
collected.
radioactivity in bioassay
samples indicates
Higher than normal background on personnel
radiological control
contamination survey devices.
measures are not being
effectively implemented
Higher than normal background radiation levels on
area monitors and air samples.
Routine radiation contamination surveys
conducted by the Radiological Control
Organization.