| DOE-HDBK-1106-97
APPENDIX D
Lesson Plan
Instructor's Notes
I.
RELEASE OF MATERIALS
A. Monitoring Techniques General
Monitoring techniques for release of materials are
addressed in DOE/CH-9401 (1993). The following
techniques apply for G-M detectors (H-3 cannot be
measured).
1. Surveys should be conducted in a low background area
(background levels are not to exceed 300 cpm; lower
levels are preferable and in most cases achievable).
2. Direct measurement should be made prior to smear
surveys.
3. Materials or equipment with inaccessible surface areas
should be disassembled for survey or the inaccessible
areas evaluated for contamination with special survey
techniques or by review of process knowledge.
If potential for internal contamination cannot be
adequately assessed, material may not be released.
4. An audible response should be utilized as the principal
indicator for initial detection of surface radioactivity.
106
|