1. An initial screening evaluation may be conducted by
wiping 100 percent of surface.
2. These large-area wipes may be evaluated by holding
the probe up to the swipe (~5 sec.).
3. If initial screening evaluation indicates presence of
contamination, take representative disc smears (100
cm2 spill area) of up to 100 percent of accessible
surface areas.
D.
Documentation
All surveys for release shall be documented in writing.
Documentation of release from controlled areas should
include information required by RCS Article 421.5.
108