| DOE-HDBK-1106-97
11. Special Considerations:
Cannot be measured directly with a thin-window G-M probe (standard survey
meter).
Can be absorbed through the skin.
Many compounds readily penetrate gloves and skin. Handle these compounds
remotely, wear two pairs of gloves, and change the outer layer at least every 20
minutes.
Tritiated DNA precursors are considered more toxic than tritiated water.
However, they are generally less volatile and do not present a significantly
greater hazard.