| DOE-HDBK-1106-97
Instructor's Notes
4.0
Volume Contamination
EH-412 has provided guidance for release of material that has
been contaminated with tritium (reference DOE 1995). Other
materials may be released if criteria and survey techniques are
approved by DOE.
5.0
Items With Fixed Contamination
Under exceptional conditions, materials and equipment with
fixed contamination that exceeds the release criteria may be
released for use in Controlled Areas outside of Radiological
Areas. As a condition of such release, the removable
contamination levels must be below the level specified in
Appendix D of 10 CFR 835. The materials shall be routinely
monitored, clearly labeled and/or tagged to alert personnel of
the contaminated status, and have appropriate administrative
procedures established and exercised to maintain control of
these items.
6.0
Covering of Contaminated Surfaces
Radioactivity on equipment should not be covered by paint,
plating, or other covering material unless contamination levels,
as determined by a survey and documented, are below the
"Removable" Criteria of Table 1 of DOE Order 5400.5, Ch. 2
(see below). A reasonable effort must be made to minimize the
contamination prior to use of any covering.