Prompt Radiation Monitoring
Prompt radiation monitoring is to ensure radiation levels outside of
accelerator facilities are maintained below regulatory limits to workers
and the general public, and as a means to detect deficiencies in beam
containment.
1.
Prompt radiation surveys may utilize fixed and portable
instruments.
2.
Pulsed radiation
Prompt pulsed radiations must be measured with specialized
survey instruments. Ion chambers are typically used.
3.
Neutron radiation.
Neutron monitoring is complicated and should be performed
by an individual qualified to perform neutron surveys.
D.
Residual Radiation
Radioactive materials may be found at accelerator facilities in the form
of:
Removable contamination.
N
Fixed contamination.
N
Activated materials.
N
Volume contamination.
N
1.
Residual radiation monitoring
Residual radiation is typically monitored with portable
instruments and contamination swipes. Types of monitoring
may include:
Work areas.
N
Items/materials.
N
Operational systems.
N