7.5.3 Special Considerations During Decommissioning Activities
Before decommissioning or disposal of any facilities or equipment, an evaluation should be
performed to assess the potential holdup of fissionable material in any equipment. These types of
measurements may require the assistance of radiological control staff.
criticality safety specialists should be consulted when using these coatings to decontaminate surfaces
because criticality could be a concern, depending on the geometry of the removed coating when in the
disposal unit.