B. Dose Equivalent Limits and Administrative Control Levels
Table 3-7
Dose Equivalent Limits and Controls
DOE Dose
DOE
Facility
Equivalent
Recommendations
Administrative
Limit
Control Level
rem/year
rem/year
rem/year
Whole body
5
2
facility-specific
Extremity
50
N/A
facility-specific
Skin & other
50
N/A
facility-specific
organs
Lens of the
15
N/A
facility-specific
eye
Member of
0.1
N/A
facility-specific
the public
Declared
0.5/gestation
N/A
facility-specific
pregnant
period
worker
NOTE: 1) The chart is based on limits and control levels for routine conditions. The limits and control levels are also based on
the sum of internal and external dose. External dose is from sources outside the body. Internal dose is from sources inside the
body. 2) The internal dose reported in a given calendar year is actually the projected dose the individual will receive over the next
50 years from intakes in that calendar year. Radioactive material may be inhaled, ingested, or absorbed through the skin or open
wound.
1. Whole body
a. Definition
The whole body extends from the top of the head down to just below the elbow
and just below the knee. This is the location of most of the blood-producing and
vital organs.