Lesson Plan
Instructor's Notes
o
If more than one step-off pad is used, the
final step-off pad is "clean," outside the
exit point, and adjacent to the boundary of
the Contamination Area.
b.
Remove protective clothing carefully and
slowly.
Loose contamination on the clothing can be
dislodged causing a possible spread of
contamination or even potential inhalation if
contamination becomes airborne.
c.
Perform a personal survey. If contamination is
indicated:
o
Stay in the area.
o
Notify Radiological Control personnel.
In some cases,
Radiological Control
o
Take action to minimize cross-
personnel may perform
contamination (e.g., put a glove on a
the survey. Tritium
contaminated hand or tape over
cannot be detected with
contamination on clothing).
standard survey meters.
Reference: 10 CFR
d.
Tools or equipment being removed from a
835.1101 requirements.
posted area must be monitored prior to release.
e.
After exiting and monitoring yourself, it is a
Insert facility-specific
good practice to wash your hands.
procedures.