Smear Surveys for Releasing Material
1. An initial screening evaluation may be
conducted by wiping 100 percent of surface.
2. These large-area wipes may be evaluated by
holding the probe up to the swipe (~5 sec.).
3. If initial screening evaluation indicates presence
of contamination, take representative disc
smears (100 cm2 spill area) of up to 100 percent
of accessible surface areas.
D.
Documentation
All surveys for release shall be documented in
writing. Documentation of release from controlled
areas should include information required by RCM
Article 421.5.