| DOE-HDBK-1130-98
Module 10.1: Sample Job Scenario
Attachment 3
ATTACHMENT 3 - Sample Job Scenario
Each facility should develop a job scenario and record it on a facility-specific RWP. (Refer to DOE
Radiological Control Technical Standard for guidance on the development of RWPs.) The following is an
example of a job scenario and radiological information.
Enter mock-up area and move the box that is located on the floor in a
JOB DESCRIPTION:
lower dose rate area to the storage cabinet located in the area. (A
contamination area is located near the Job Site.)
Mock-up area, Building 2.
LOCATION:
RWP not valid for Contamination Area.
SPECIAL INSTRUCTIONS:
Avoid drum in Radiation Area.
80 mR/hr near drum on left side of work area.
RADIATION LEVELS:
25 mR/hr near cabinet and panel on north wall.
5 mR/hr near step-off pad area.
CONTAMINATION LEVELS:
None.
PROTECTIVE CLOTHING:
TLD and pocket dosimeter (self-reader).
DOSIMETER(S):
130
|