DOE-HDBK-1204-97
APPENDIX C
TEST ITEM EXAMPLES
(d)
No adjustments required, the inherent power coefficients will maintain the
reactor at constant power.
Answer: (b).
C.4 Essay Test Item Examples
Satisfactory:
Test item:
Assume the reactor is at 100% power. For each of the following reactor protective
system trips, state (a) the sensed parameter, (b) the limiting safety system setting
(LSSS), and (c) the protection provided.
(1)
High power level trip (3 points)
(2)
Low reactor coolant flow trip (3 points)
(3)
Steam generator differential pressure trip (3 points)
Answer:
(1)
(a)
Neutron flux (thermal backup) is sensed.
(b)
LSSS @ 100% is 107% of rated power.
(c)
Prevents clad damage due to reactivity excursions too rapid to be
detected by pressure/temperature trips.
C-12


Privacy Statement - Press Release - Copyright Information. - Contact Us