| DOE-HDBK-1204-97
APPENDIX C
TEST ITEM EXAMPLES
Answer:
(a)
Neutron flux (thermal backup) is sensed (0.3)
LSSS @ 100% is 107% of rated power (0.2)
Prevents clad damage due to reactivity excursions too rapid to be detected by
pressure/temperature trips (0.5)
(b)
RCS differential pressure across each SG is sensed (0.3)
LSSS @ 100% is 95% of max flow (0.2)
Protects against DNB (0.5)
(c)
Secondary differential pressure across each SG is sensed (0.3)
LSSS @ 100% 135 psid (0.2)
Protects the core against DNB (0.5)
(d)
LSSS @ 100% is 5 psig (0.1)
Assures reactor is tripped whenever SG is sensed (0.4)
Reference: FCS TS 1.3, p. 1-7 to 1-10.
Comment:
C
The developer has assigned different values to responses (i.e., state the
sensed parameter, limiting safety system setting, and what each trip protects
against).
C
Abbreviations are used instead of complete wording.