| DOE-STD-1029-92
Appendix B
SOP-618-4
Revision 0
Approved October 22, 1991
Page 11 of 16
6
PLUG WELDING (continued)
[14]
Adjust the transducer bracket until the motion readout indicates 0.4000
(acceptable range of 0.3995 - 0.4005).
[15]
Verify "Flow Normal" indicator light on the control panel is on.
NOTE
The low flow switch to the welder is pre-set to 0.75 gpm.
[16]
IF "Flow Normal" indicator light is not on,
THEN rotate the water filters to attempt to correct the flow conditions,
AND verify that "Flow Normal" indicator light is on.
[17]
IF "Flow Normal" light is still not on,
THEN STOP this procedure,
AND contact supervisor immediately.
[18]
Verify "Pressure Normal" indicator light on the control panel is on.
[19]
IF the "Pressure Normal" indicator light is not on,
THEN adjust the pressure switch located on the side of the welder head
to a slightly lower setting
AND verify the "Pressure Normal" indicator light is on.
[20]
IF "Pressure Normal" light is still not on,
THEN STOP this procedure,
AND contact supervisor immediately.
B - 12
|