| DOE-STD-1029-92
C Inadvertent, incorrect, or omitted actions that may result in limiting
conditions for operation as defined in the technical safety requirements
C Limitations identified in approved vendor information
C Limitations identified in applicable design documents
C Unusual alarms affecting facility availability that may occur or are expected
to occur as a result of performing the procedure
C Mechanical or electrical bypasses (lifted leads, inhibits, jumpers, and fuse
removals) used in performing the procedure
C Electrical and mechanical interlocks involved in performing the procedure
C Actions resulting in emergency response or automatic incident response
C Undesirable consequences of violating each precaution or limitation
statement.
EXAMPLE 3-13. Precaution statements.
2
PRECAUTIONS AND LIMITATIONS
2.1
Vapor pressure thermometer capillary tubing can be damaged if rolled up less than
8 inches in diameter.
2.2
The instrument terminals may carry hazardous electrical currents. You may
receive severe or fatal electric shock if you touch these terminals without
protection.
EXAMPLE 3-14. Limitation statement
2
PRECAUTIONS AND LIMITATIONS
2.1
The unavailability of the standby motor generator during power operations may
exceed a technical safety requirements limiting condition of operation.
25
|