| DOE-STD-1041-93
appropriate. Approved supplemental lighting (e.g., flashlight, droplight, portable
lighting) should be used to inspect dimly lit work station areas. A checklist may
be used to ensure that all items are inspected. A list of some possible inspection
items is contained in Appendix A.
4.1.3.2 Equipment Status Checks
The status of equipment (i.e., operating, standby, work-in-progress, or
out-of-service) should be determined to ensure proper response to any problems
that may arise. Some possible status checks are as follows:
C
Operating Equipment
-
Motor and pump housing temperatures are within acceptable limits
-
System temperatures, pressures, and flows are within acceptable limits
-
Proper belt and coupling tightness
-
System leakage is within acceptable limits
-
Noise and vibration is within acceptable limits
-
Ventilation system intakes clear of debris
-
Equipment grounding straps connected
-
Power consumption (Amps, Fuel Oil)
C
Standby Equipment
-
Proper valve/circuit breaker lineup (spot check)
-
Oil levels are within acceptable limits
-
No unusual noises, smells, temperatures, or pressures
C
Out-of-Service Equipment
-
Boundary components in correct position (spot check).