DOE-STD-1121-98
3.1.3 Participation in Bioassay Program
C
rationale for selection of workers for bioassay monitoring
3.1.4 Detection and Confirmation of Intakes
C
biokinetic models
C
model parameters
C
assumptions
C
justification of the choices of default parameters used in deriving a DIL
C
parameters and their associated default values used in dosimetric modeling and
evaluation, such as
-intake date
-deposition probabilities (deposition fractions)
-retention functions
-organ masses
-absorption fractions
-facility-specific factors
C
statistical methods for
-evaluating bioassay data
-identifying bioassay results above environmental background values
-using appropriate blanks
-analyzing trends
-MDAs
C
description of a procedure for evaluating doses if the time course of an intake cannot
be plausibly established
C
if DAC-h calculations are used to assess exposures to airborne radioactive materials,
a description of any authorized adjustment(s) to such calculations to account for the
use of respiratory protection