| MODULE NO:
PAGE
4 OF
6
STEP
S/C
T/E
TRAINEE
INITIALS
NO.
CODE
CODE
PROMPT
OJT/EVAL
3
C
P
When "Insert Hands" prompt
is displayed, insert hands
into detector openings,
pressing the ends of the
fingers firmly against the
stoppers so that the outer
detectors press against
hands.
/
Standard:
Jewelery that may damage the detector should not
be worn on hands.
Standard:
Remain in this position until count is complete.
OJT ENABLING OBJECTIVE NO. 2:
DEMONSTRATE THE PROPER USE
OF THE BERTHOLD MONITOR TO CHECK FOR CONTAMINATION ON THE
BODY.
STEP
S/C
T/E
TRAINEE
INITIALS
NO.
CODE
CODE
PROMPT
OJT/EVAL
1
P
Remove frisker from the
hook before moving feet.
/
2
C
P
Frisk starting at the top of
your head. Proceed downward,
checking your nose, mouth and
neck.
/
3
P
Check shoulders, arms, then
the torso and finally the
legs and feet.
/
Standard:
Move the frisker a maximum of 2 to 3 inches per second.
This is necessary to allow the meter time to respond. If
you move the probe too fast, you may
pass over
contamination and not record it. If an audible increase
in the count rate is noted, return the probe to the spot
and hold for a minimum of five seconds to determine if
contamination is actually present.
BADGE:
DATE:
OJT INSTRUCTOR SIGNATURE:
EVALUATOR SIGNATURE:
BADGE:
DATE:
TRAINEE/INCUMBENT SIGNATURE:
BADGE:
DATE:
B-15
|