| DOE-STD-1050-93
A PPEN D IX C
EXAMPLES OF MINOR MAINTENANCE
Examples of Mechanical Minor Maintenance
A. The following are examples of work that may qualify as minor maintenance:
1. Manual Valve: Adjust packing on manual valves not subject to testing, repair or
replace handwheel, lubricate valve stem.
2. Pumps: Adjust packing; adjust cooling water flow.
3. Flanges: Tighten to stop leakage (not to exceed recommended torque values).
4. Diaphragms: Seal against in-leakage.
5. Brackets/Hangers: Replace missing bolts (except safety-related/seismically qualified or
material substitution).
6. Doors: Repair or replace knobs, hinges, bars, or closures.
7. Plumbing: Repair or replace commodes, water fountains, sinks.
8. Structures: Patch walls, roofs, etc. (except fire barrier seals).
9. Grating/Stair Treads: Repair or replace grating, clips, or treads.
B. The following are examples of work that does not qualify as minor maintenance:
1. Manual Valves: Adjust packing on valves that require testing.
2. Motor-operated Valves: Adjust or replace packing.
3. Pumps: Replace packing or seals, replace casing bolts, replace gasket.
4. Flanges: Replace gasket or fasteners; install or remove blank flange.
C-3
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |