1.7 Corrective Action Follow-up
1.7.1 Equipment that has been found to have a known or suspected lubricant problem may be
sampled at more frequent intervals as recommended by the laboratory or as requested
by the predictive maintenance coordinator until the suspected problem has been
resolved or corrective action has been taken.
1.7.2 Following any corrective action, a follow-up sample should be taken promptly to
reestablish the "baseline" for the equipment in question and to ensure that the action
taken was adequate.
1.8 Program Upgrading
1.8.1 The predictive maintenance coordinator should continually seek to refine and improve
the lubricating oil analysis program by the following:
a. maintaining an awareness of actual and suspected equipment operating problems
b. evaluating the potential for oil sampling and analysis methods to aid in detecting
and identifying equipment problems
c. revising the program as appropriate to take advantage of improved sampling and
analysis techniques as they become available
1.8.2 Upgrading of the program may entail increasing or reducing the requirements in terms
of equipment included in the program and time interval between examples.
1.8.3 Failures of equipment included in the lubricating oil analysis program should have
detailed root cause investigations to determine why the programs did not detect
degradation before the failures occurred.