DOE-STD-1091-96
facilities; however, fragmentation shielding is
required.
(b)
(08) 1.2 Munitions. Inhabited buildings and public
traffic route separation distances shall be as
specified in Table 9-7, DOD 6055.9-STD. If the
minimum distance specified is available, there is
no limit as to the quantity of material that may be
stored in an approved structure. If the minimum
distance is not available, the structure shall not be
used for this material.
(12) 1.2 Munitions. Inhabited buildings and public
(c)
traffic route separation distances shall be as
specified in Table 9-8, DOD 6055.9-STD. If the
minimum distance is not available, the structure
shall not be used for this material.
5.4.3.3
Hazard Class/Division 1.3 Munitions
(a)
Inhabited buildings and public traffic route
separation distances shall be as specified in Table
9-10. DOE 6055.9-STD, for Hazard Class/Division
l.3 munitions.
(b)
If the Hazard Class/Division 1.3 material is further
described by a numerical figure in parenthesis, that
number in hundreds of feet shall be minimum sepa-
ration distance required, regardless of the distances
given in Table 9-10 for the specific
quantity.