| DOE-STD-3025-99
C
Verifying compliance with qualification requirements by review of
records.
C
Inspection for shipping damage at time of receipt.
C
Preparing of filters for shipping, including the proper loading in
transport vehicles.
9.1.2
Inspection and Testing. Personnel responsible for inspection and testing of
HEPA filters, for the supervision of inspection and testing, or for the
interpretation of inspection and test results shall have had formal training and
demonstrated performance or comprehension in the following:
C
All applicable provisions of this standard.
C
Applicable specifications for HEPA Filters used at DOE nuclear
facilities.
C
Materials, construction and performance specifications of HEPA filters.
C
Use and interpretation of filter specifications and customer purchase
criteria, with particular attention to ASME AG-1 Code, Section FC
(formerly Military Specifications MIL-F-51068), MIL-F-51079, and
Institute of Environmental Sciences publication IES-RP-CC-001.3.
C
Performance specifications for test devices and other instruments used at
the FTF.
C
Procedures for handling, inspection, testing data, recording, labeling,
and disposition of accepted and rejected filters.
C
Proficiency in the operation, adjustment, and maintenance FTF
instruments and equipment.
9.1.3
Certification of Test Results. Personnel responsible for interpretation or
certification of inspection and test results shall, in addition to the requirements
of section 9.1.2 of this standard, have demonstrated proficiency in the
following:
C
Data evaluation and analysis, including validation of test results.
13
|