| ![]() DOE-HDBK-1105-2002
Radiological Training for Tritium Facilities
Student's Guide
Notes
4.
Dilution Ventilation
Dilution ventilation is the once-
through flow technique of
exchanging outside air for inside air
for comfort and the reduction of
airborne sources.
5.
Storage
Tritium can be stored in storage
beds. Metal tritide and uranium
hydride are the most common for
these storage systems. Tritium is
generally released by heating the
metal tritide.
B.
Administrative Controls
There are many administrative controls to reduce
doses. The following are just a few that should
apply to all sites:
limitation of access time
N
procedures/RWPs
N
N
For tritium and tritium compounds, 10 CFR 835
Appendix D requires posting contamination areas
based on removable contamination values of 10,000
dpm/100cm2.
16
|