| DOE-HDBK-1108-2002
Radiological Training for Accelerator Facilities
Instructor's Guide
Lesson Plan
Notes
4.
Test mode
Certain devices, (e.g., magnets) may be energized to allow
testing. Limited personnel may access but must be aware of
hazardous conditions (e.g. electrical power).
5.
Exclusion mode
Beam may be present. No access is allowed.
EO-13 DISCUSS
D.
Configuration Control Program
site configuration
control program.
The facility design must continue to meet its intended function while
providing for adequate personnel safety. Configuration control ensures
that only authorized changes are made and that any changes made
continue to provide adequate personnel safety.
1.
Elements of a program
Configuration control programs for accelerator facilities
include:
Inventory and labeling of controlled devices.
N
Periodic inspections.
N
Procedures for change and/or restoration of
N
configuration.
Testing to verify proper configuration.
N
Show picture of a
2.
Structures and equipment.
device that is
labeled as a
These must be maintained in a specific configuration to
configuration
perform the desired safety function.
controlled item.
Examples include:
Radiation shielding.
N
Magnets.
N
Stops.
N
N
Interlocks and access system wiring.
N
EO-11 DISCUSS
3.
(Facility-Specific) configuration control procedures.
site configuration
control program.
24
|