3. Filter, or provide ferrite beads for, signal lines from the equipment which may conduct EMR
emissions into EED circuitry or secondarily radiate EMR in the proximity of an EED thus
causing a threat of detonation.
4. Ensure that the minimal power necessary is used to operate circuitry capable of producing
EMR.
5. Label the equipment capable of emitting EMR to indicate the minimum separation distance
to be maintained between the equipment and an EED or EEDs.
6. Use a safety factor in design for EMR reduction; e.g., only 1/10 of the energy that would
initiate an EED is allowed.