DOE-HDBK-1129-99
-
Package meets general design requirements for radioactive material packaging from
49 CFR 173.410
-  Nonfixed/removable contamination on the external surface of the package is < limit
in 49 CFR 173.443 (0.41 Bq of tritium/cm2 or 22 disintegrations/min (dpm)/cm2 for
tritium)
-  Outside of inner or outer packaging is marked "Radioactive"
Low Specific Activity (LSA) A quantity of Class 7 (radioactive) material with limited
specific activity
-  LSA-I
  Earth, concrete, rubble or other debris = 4 x 105 TBq of tritium/g (0.001 Ci of
tritium/g, 1 Ci of tritium/kg or 2.2 lb/Ci of tritium)
-  LSA-II
  Tritium-Contaminated Water up to: 0.8 TBq of tritium/L (20.0 Ci/L)
  Solids and Gases up to 0.004 TBq of tritium/g (0.1 Ci/g, 100 Ci/kg)
  Liquids 4 x 104 TBq of tritium/g (0.01 Ci/g, 10 Ci/kg)
-  LSA-III
  Solids, consolidated wastes, or activated material that meet 49 CFR 173.468
water leach test; and
  Uniformly distributed in a collection of solid objects or uniformly distributed in
solid compact binding agent; i.e., concrete, bitumen, ceramic, etc.
  Relatively insoluble or intrinsically contained in relatively insoluble material such
that, under loss of packaging and placed in water for seven days, would not
exceed 4 TBq of tritium (108 Ci of tritium)
  The average specific activity of the solid does not exceed 0.08 TBq of tritium/g
(2.16 Ci/g)
SCO (Surface Contaminated Object) Non-radioactive solid objects with Class 7
(radioactive) materials distributed on the surfaces
-  SCO-I
  Nonfixed contamination on accessible surface averaged over 300 cm2 is < 4 Bq
of tritium/cm2 (104 Ci/cm2 )
  Fixed contamination on the accessible surface averaged over 300 cm2 is < 4 x
104 Bq of tritium/cm2 (1 Ci/cm2 )
  Nonfixed plus fixed contamination on the inaccessible surface averaged over 300
cm2 is < 8 x 105 Bq of tritium/cm2 (20 Ci/cm2)
-  SCO-II
Solid object on which limit for SCO-I is exceeded and meets the following:
  Nonfixed contamination of accessible surface averaged over 300 cm2 is < 400 Bq
of tritium/cm2 (10-2 Ci/cm2).
  Fixed contamination of accessible surface averaged over 300 cm2 is < 8 x 105 Bq
of tritium/cm2 (20 Ci/cm2).
  Nonfixed plus fixed contamination of accessible surface averaged over 300 cm2
is < 8 x 105 Bq of tritium/cm2 (20 Ci/cm2).
Type A Packages limited to 40 TBq of tritium (< 1080 Ci) per package
Type B Packages for quantities > 40 TBq of tritium (> 1080 Ci) per package
Graded Safeguards Program
-  Category III: Weapons or test components, containing reportable quantities > 50 g T2
with isotopic fraction T2 > 20 percent
-  Category IV: All other reportable quantities