| DOE-STD-1029-92
Appendix B
SOP-618-4
Revision 0
Approved October 22, 1991
Page 13 of 16
6
PLUG WELDING (continued)
NOTE
The nominal values and the acceptable ranges are presented in the
table in step [26].
[26]
Verify readings are within the limits specified:
No Tube
Step Stub Weld
Parameter
Current, amps
5000 (4500-5500)
4000 (3500-4500)
Force, lbf
1000 (950-1050)
1000 (950-1050)
Cycles, Hz
25 (20-30)
25 (20-30)
[a]
IF the recorded readings are within the limits,
THEN mark "YES" in the "Within Limits" column of the
Check Sheet/Data Sheet
[b]
IF the recorded readings are not within the limits,
THEN mark "NO" in the "Within Limits" column of the
Check Sheet/Data Sheet
[27]
Switch station selector OFF.
[28]
Push emergency stop button to retract piston.
[29]
Remove reservoir from welder.
B - 14
|