DOE-HDBK-XXXX-2005
06/30/2005
FISSIONABLE MATERIALS. A nuclide capable of sustaining a neutron-induced chain
245.
reaction (e.g., uranium-233, uranium-235, plutonium-238, plutonium-239, plutonium-
241, neptunium-237, americium-241, and curium-244). [10 CFR 830.3]
246.
FISSIONABLE MATERIALS HANDLER. A person certified by contractor facility
management to manipulate or handle significant quantities of fissionable materials, or
manipulate the controls of equipment used to produce, process, transfer, store, or package
significant quantities of such materials. [DOE O 5480.20A] [EH62dd1]
247.
FLAME RESISTANT (FR): The property of a material whereby combustion is
prevented, terminated, or inhibited following the application of a flaming or non-flaming
source of ignition, with or without subsequent removal of the ignition source. [NFPA
70E]
248.
FLAME SPREAD RATING. Flame spread rating is a numerical classification
determined by the test method in American Society of Testing and Materials standard
ASTM E-84, which indexes the relative burning behavior of a material by quantifying the
spread of flame of a test specimen. The surface burning characteristic of a material is not
a measure of resistance to fire exposure. [DOE-STD-1066-97]
FLAMMABLE LIQUID. A liquid having a closed cup flash point below 100oF (38oC)
249.
and having a vapor pressure not exceeding 40 psia (2068 mm Hg) at 100oF (38oC).
[DOE-STD-1066-97]
250.
FLASH HAZARD. A dangerous condition associated with the release of energy caused
by an electric arc. [NFPA 70E]
251.
FLASH HAZARD ANALYSIS. A study investigating a worker's potential exposure to
arc-flash energy, conducted for the purpose of injury prevention and the determination of
safe work practices and the appropriate levels of personal protective equipment. [NFPA
70E]
FLASH PROTECTION BOUNDARY. An approach limit at a distance from exposed
252.
live parts within which a person could receive a second degree burn if an electrical arc
flash were to occur. [NFPA 70E]
253.
FLASH SUIT. A complete flame resistant clothing and equipment system that covers the
entire body, except for the hands and feet. This includes pants, jacket, and bee-keeper-
type hood fitted with a face shield. [NFPA 70E]