| DOE-STD-1021-93
SSC is a "safety-class" item as defined in Section 2.3 (a), and
its failure due to an NPH event would result in off-site
release consequences greater than or equal to the
PC-4
unmitigated release associated with a large (200 MW)
Category A reactor severe accident
SSC failure has adverse release consequences greater than
PC-3
safety-class SSC Evaluation Guidelines, but not severe enough
to place it in PC-4.*
a. SSC performs emergency functions to preserve health and
safety of workers as defined in Section 2.4(d),
PC-2
b. SSC is part of a building used for assembly of more than
300 persons in one room,
c. It has been classified "safety-significant."
a. SSC is a building/structure with potential human
occupancy, or
b. SSC failure may cause fatality or serious injuries to in-
PC-1
facility workers, or
c. SSC failure can be prevented cost-effectively by NPH
design.
PC-0
Figure 2-1
Basic Guidelines for Preliminary NPH Performance Categorization of
Structures, Systems, and Components
Notes:
SSC = Structure, System, or Component
Use this Figure only in the context of Section 2 of this document; also see Subsection 2.5 for System
Interaction Effects
* Also Refer to DOE-G-420.1-2 for additional applications.