f.
Using the guidance in DOE-STD-1073-93, Guide for Operational Configuration
Management Program, discuss the System Engineer concept as it applies to
oversight of safety systems. Specifically address the areas of configuration
management, assessment of system status and performance, and the technical
support for operation and maintenance activities or for Documented Safety Analysis
reviews.
13. Waste management personnel shall demonstrate a familiarity level knowledge of
monitoring techniques and monitoring equipment related to environmental
compliance.
Supporting Knowledge and/or Skills
a.
Describe the types of equipment used to monitor a site for the following:
Ambient air quality
Emissions
Meteorological factors
River and stream contamination
Soil and sediment contamination
Wildlife contamination
b.
Describe the requirements of the following documents as they relate to
environmental monitoring:
Comprehensive Environmental Response, Compensation, and Liability Act
(CERCLA)
Resource Conservation and Recovery Act (RCRA)
National Environmental Policy Act (NEPA)
40 CFR 61, NESHAPs
c.
Describe the various quality assurance and quality control programs used to
enhance data quality. Include in your discussion programs both internal and external
to the Department.
d.
Describe the standard methods for the examination of water and wastewater.
e.
Given a sampling parameter/equipment, describe the standard sampling methods
and protocols.
f.
Explain the reason for measuring emissions, meteorological factors and ambient air
quality under various operation conditions (e.g., routine and emergency).
g.
Describe the purpose and limitations of the following air quality measurement
instruments:
High volume particulate sampler
Liquid bubbler (e.g., for sulfur dioxide)
Infrared spectrometer