DOE-HDBK-3010-94
7.0 Application Examples; Seismic Release Example
Surface Area (ft2)
g Pu/ft2
Glovebox
Multiple
Contamination
(g Pu)
Feed Prep.
470
1.25
0.1
59
3 Dissolvers
840
1.25
0.01
11
Sample
560
1.25
0.01
7
IX and Evap.
880
1.50
0.01
13
H2O2 Precip.
440
1.50
0.1
66
Dry Line
1320
1.50
0.1
200
1400
1.25
0.1
175
Reduction
Total
531
The bounding ARF and RF values assessed for vibration-shock impact of loose
surface contamination on an unyielding surface are 1E-3 and 1.0 (subsection 5.2.3.2).
The resulting cumulative initial respirable source term in glovebox atmospheres due to
surface contamination is:
531 g * 1.0 * 1E-3 * 1.0 = 0.5 g.
Similar estimates could be made for surface contamination in a HEPA filter plenum.
For a plenum 15 ft long, 10 ft wide, and 10 ft high, the basic enclosure surface area
is 600 ft2. An individual wall for a bank of HEPA filters has a surface area,
discounting HEPA filter face area, of 100 ft2, or 200 ft2 on both sides. If there are
four banks of HEPA filters, the total additional surface area is bounded by an
estimate of 800 ft2. Given that there is not visible surface contamination in a
significant part of the plenum, the 1400 ft2 could be considered powder handling area,
yielding an overall surface contamination estimate of 140 g Pu, which would yield an
airborne source term of 0.1 g Pu in the plenum, as no release is anticipated from the
filters themselves.
The same logic could be applied to plutonium contamination in ventilation ductwork if
significant quantities are assumed or known to be present. If the material in the
ductwork was a hard, rock-like substance, or a sticky oily residue, no significant
release from the residue would be postulated. If, however, it was fine, loose surface
contamination, the source term could be estimated in the same manner it was for
gloveboxes or the filter plenum.
B. 0.26 g Event. The only significant addition to the release phenomena postulated
for the 0.13g event is the failure of one or two plutonium process solution tanks. It is
noted, however, that the failure of glovebox connections may yield a higher glovebox
Page 7-69