DOE-HDBK-1099-96
APPENDIX B - EXAMPLE DRILL SCENARIOS
Title:
Evaporator Feed Tank Header Line Leak
Drill Number:
WEACDC04
Revision Number: 0
*  Recorded time in the appropriate section
of 241-FH-9562.
Supervisor/Manager
Notified SRSOC immediately.
*  Classified event IAW Procedure Manual
9B5.
CONDITION
RESPONSE/EVALUATION CRITERIA
Advised Waste Management line
organization and WMEC of spill ASAP.
Supervisor/Manager personally inspected
spill area to review immediate actions taken
and recommend additional actions.
Assessed effectiveness of immediate
actions to stop and contain spill, then
request additional assistance as needed.
Radiological Controls
CUE: Personnel contamination will only
occur if operators potentially contaminate
themselves. Personnel contamination levels
Evacuated any (potentially) contaminated
vary by scenario option (A/B):
personnel
For option A: 150 CPM > bkgd
For option B: 1500 CPM > bkgd
Established personnel protection
requirements at the scene.
Obtained air sample in the spill area.
CUE: No airborne contamination
Surveyed area to assess hazards and define
CUE: 200 CPM > bkgd (option A),
spill area.
2000 CPM > bkgd (option B), No alpha
contamination (either option)
B 6-7