| DOE-HDBK-1106-97
Radiological Contamination Control Training
for Laboratory Research
Student's Guide
11.
Special Considerations:
o
Cannot be measured directly with a thin-window G-M probe (standard survey meter).
o
Can be absorbed through the skin.
o
Many compounds readily penetrate gloves and skin. Handle these compounds
remotely, wear two pairs of gloves, and change the outer layer at least every 20
minutes.
o
Tritiated DNA precursors are considered more toxic than tritiated water. However,
they are generally less volatile and do not present a significantly greater hazard.