| DOE-STD-3020-97
In order to reduce costs associated with qualification testing,
successful tests of filters with known material components for filter
frames, filter medium, cases and adhesives, produced by a single
manufacturer, can be used to qualify filters of similar construction, but
smaller sizes by the same manufacturer. Tests of:
Filter Size 5 shall qualify similar filters of sizes 1 through 5.
Filter size 6 shall qualify similar filters of sizes 1 through 6.
Filter Size 7 shall qualify similar filters of sizes 1 through 7.
Filter Size 8 shall qualify similar filters of sizes 1 through 8.
DOE reserves the right to randomly select HEPA filters from existing
storage at DOE sites and perform the tests defined in Sections 6.1.3
through 6.1.5 of this standard. If failures are noted, procurement
organizations shall be notified that the failed filter model has been
removed from the current DOE QPL. The manufacturer, the DOE
FTF, and DOE contractor procurement specialists shall be informed
that the failed filter model is no longer acceptable for use at DOE
facilities, pending requalification.
Qualifications Testing. Qualifications tests of filter components shall
6.1.2
be conducted in accordance with requirements of Sections 6.1.3
through 6.1.5 of this standard and applicable specification and
performance requirements of ASME AG-1. If a manufacturer's filter
model, consisting of a specific set of components including frame,
adhesive, and filter medium, is listed in a current QPL, this shall
constitute satisfactory evidence of having met the qualification
requirements of this standard. Filters selected for qualification testing
may be prototypes of the proposed design or production filters of the
specific design randomly selected from the manufacturer's stock.
The number of filter units required for qualification testing shall be as
specified in ASME AG-1. Modification of these requirements shall be
only as specified below.