| DOE-EM-STD-5505-96
APPENDIX G
SAMPLE OPERATIONS ASSESSMENT REPORT
FINDING:
The following unapproved operator aids were discovered:
a. TOA Intercom System Use located in building 204-AR;
b. How to Respond to an Alarm located in CASS;
c. Excerpt from Cross Site Transfer Procedure (TO-140-90 p.57) located in CASS
d. Waste Cooling Water Meters TDRC 413,414, and 415 Multiplication Aid located in
building 241-A-271. (Reference: 1, 2)
EQUIPMENT AND PIPING LABELING
REFERENCES:
1. DOE 5480.19, Chapter XVIII
2. IP-0842 Volume IV Section 3.3 Rev 0a
FINDING:
Two labels in the AP tank farm were overwritten with marker. (References: 1, 2)
DISCUSSION: The label for pump P-3 has "Mixer pump" written in marker over the label.
The label for the pump rotation motor has "Mixer" written in marker over the label.
FINDING:
In tank farm valve MK-9518 had no label, although documentation shows a label had been
installed. (References: 1, 2)
FINDING:
Several loose component labels were found (not attached to their components). (References: 1, 2)
DISCUSSION: Examples are:
1. The label for the 16-N Conductivity Probe Purge Air Valve in the N tank farm was
found on the ground.
2. The labels for the TMACS cabinets in the X/Y tank farms were found on the ground.